Solids & Complex Matrices Analyzer

Description

Available as an attachment for the RA-915+ or RA-915M analyzer, the PYRO-915 is designed for the precise determination of mercury in solids, liquids, and complex matrices such as oil.

Model

PYRO-915 Attachment (pictured with RA-915M Analyzer)

Applications

  • Mercury analysis in solids
  • Mercury analysis in liquids
  • Mercury analysis in complex matrices such as oil

Features

  • Zeeman Background Correction
  • Wide dynamic range of analysis
  • Ease of operation
  • Minimal sample preparation
  • Robust and low maintenance
  • No catalyst or amalgamation required

Specifications

  • PYRO Principle of Operation: Thermal Atomic Absorption (AA)
  • PYRO Requirement: RA-915+ or RA-915M
  • PYRO Detection Limit: 0.5 μg/kg
  • PYRO Power: 110/220 VAC, 300 W
  • PYRO Dimensions: 14” x 12” x 6” (350 x 300 x 150mm)
  • PYRO Weight: 11 lbs. (5 kg)


Related Products

RA-915+ Analyzer

RA-915+ Analyzer

More info
RA-915M Analyzer

RA-915M Analyzer

More info
RP-92 Attachment

RP-92 Attachment

More info

Description

The RA-915F combines facets of the PYRO-915 Attachment with the RA-915M Analyzer for a complete system designed for the precise determination of mercury in solids and liquids such as foodstuffs, coal, FGD slurry, fly ash, raw feed materials, and other complex matrices.

Model

RA-915F

Applications

  • Mercury analysis in liquids
  • Mercury analysis in solids
  • Mercury analysis in complex matrices

Features

  • Zeeman Background Correction
  • Wide dynamic range of analysis
  • Ease of operation
  • Robust and low maintenance
  • Minimal sample preparation
  • No catalyst or amalgamation required

Specifications

  • F Attachment Principle of Operation: Thermal Atomic Absorp. (AA)
  • F Attachment Requirement: RA-915+ or RA-915M
  • F Attachment Detection Limit: 0.5 μg/kg – 3 μg/kg (matrix depend.)
  • F Attachment Power: 110-240 VAC, 50/60Hz
  • F Attachment Dimensions: (300 x 260 x 130cm)
  • F Attachment Weight: 16.5 lbs. (7.5kg)


Related Products

RA-915+ Analyzer

RA-915+ Analyzer

More info
RA-915M Analyzer

RA-915M Analyzer

More info
RP-92 Attachment

RP-92 Attachment

More info

Description

Designed specifically for the analysis of mercury sorbent traps, the M324 Sorbent Trap Attachment is combined with an RA-915+ or RA-915M Analyzer to produce is a one-of-a-kind instrument that has been a critical tool for EPA Method 30B, Performance Specification 12B (formerly Appendix K), and Method 7473.  In addition to sorbent trap analysis, this system can be used to determine mercury concentrations in liquids and solids.

Model

M324 Attachment (pictured with RA-915M Analyzer)

Applications

  • Sorbent Trap Mercury Analysis
  • Mercury Analysis in Liquids
  • Mercury Analysis in Solids

Features

  • Zeeman Background Correction
  • Wide dynamic range of analysis
  • Ease of operation
  • Minimal sample prep
  • Robust and low maintenance
  • No catalyst or amalgamation required

Specifications

  • Principle of Operation: Thermal Atomic Absorption (AA)
  • Must be used with RA-915+ or RA-915M
  • Detection Limit: < 0.5 ng
  • Power: 110/240 V, 50/60 Hz, 120 VA
  • Dimensions: 23.6” x 19” x 8.6” (600 x 480 x 220mm)
  • Weight: 45 lbs. (20 kg)

 